Please use this identifier to cite or link to this item: https://repositorio.unichristus.edu.br/jspui/handle/123456789/1652
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCANDEIRO, George Táccio de Miranda-
dc.contributor.authorGONÇALVES, Francisco Nathizael Ribeiro-
dc.date.accessioned2024-01-30T11:16:14Z-
dc.date.available2024-01-30T11:16:14Z-
dc.date.issued2023-
dc.identifier.citationGONÇALVES, Francisco Nathizael Ribeiro. Influência da conicidade do canal radicular na leitura de dois localizadores eletrônicos foraminais. 2023. Dissertação (Mestrado Acadêmico em Ciências Odontológicas) - Centro Universitário Christus, Fortaleza, 2023.pt_BR
dc.identifier.urihttps://repositorio.unichristus.edu.br/jspui/handle/123456789/1652-
dc.description.abstractA presente pesquisa analisou a influência da conicidade do canal radicular na acurácia dedois LEFs. Foram utilizados 25 raízes disto-vestibulares de molares superiores humanos extraídos e pertencentes ao banco de dentes da Unichristus. Para a determinação da posição do FA, foi realizado o acesso com ponta diamantada esférica #1014 e as coroas foram seccionadas utilizando-se ponta diamantada #3080. A lima anatômica inicial foi a tipo K #10, sendo levada ao canal radicular até que sua extreminade fosse visualizada (patência foraminal) com o auxílio de um microscópio clínico (aumento de 16X). Dentes sem patencia foraminal e calcificações foram excluídos do estudo. As leituras odontométricas foram realizadas com dois diferentes LEFs (Root ZX II e Romiapex A- 15), considerando o ponto de referência eletrônica 0.0 (ápice) em cada aparelho. Todas as medições foram realizadas em triplicada, sendo utilizada a média aritmética dos três valores. Com o auxílio de um paquímetro digital foram registrados as medidas e lançadasem planilha no Excel. Após verificação visual com a lima k #10, os canais foram instrumentados com a lima #25.01 para que a região apical fosse padronizada e em seguida foram instrumentados com as limas #25.02, #25.04, #25.06, #25.08, #25.10 e #25.12, e a cada instrumentação, a odontometria eletrônica era conferida com a #25.02. Foi adotado a medida 0.0, e as margens de erro de ±0.5 e ±1.0. As discrepâncias entre asleituras visuais e eletrônicas foram analisadas estatisticamente pelo teste ANOVA e Bonferroni, sendo considerado significante quando P<0,05. Utilizando a marcação 0,0, ea margem de erro de ±1.0, foi observada que as leituras dos aparelhos eram semelhantes nos condutos com diferentes conicidades (P>0,05), havendo uma tendência maior à submedições. Porém, quando se utilizou a margem de variação da medição em ±0.50, houve diferenca estatística significante no grupo do Romiapex A-15 (P=0,0248) e quandose compara os resultados dos dois LEFs. Dessa forma, concluiu-se que, a conicidade do conduto não influenciou significantemente a precisão dos LEFs avaliados, tendo como ponto de referência 0.0. Utilizando a margem de variação de ±0.5, o aparelho RomiapexA-15 apresentou maior acurácia e, por fim, na margem de erro de ±1.0 ambos os LEFs apresentaram excelente precisão.pt_BR
dc.language.isopt_BRpt_BR
dc.subjectendodontiapt_BR
dc.subjectodontometriapt_BR
dc.subjectlocalizador eletrônico foraminalpt_BR
dc.titleInfluência da conicidade do canal radicular na leitura de dois localizadores eletrônicos foraminaispt_BR
dc.typeDissertaçãopt_BR
dc.title.inglesInfluence of the taper of the root canal on the reading of two electronic apical locatorspt_BR
dc.description.resumo_abstractThe present research analyzed the influence of root canal taper on the accuracy of two EALs (Electronic Apex Locators). Twenty-five disto-vestibular roots from extracted human upper molars belonging to the Unichristus tooth bank were used. To determine the position of the apical foramen (AF), access was made with a spherical diamond tip #1014, and the crowns were sectioned using a diamond tip #3080. The initial anatomic file used was a K-type #10, which was taken into the root canal until its tip was visualized (foraminal patency) with the aid of a clinical microscope (16X magnification). Teeth without foraminal patency and calcifications were excluded from the study. Odontometricreadings were taken with two different EALs (Root ZX II and Romiapex A-15), with the electronic reference point set at 0.0 (apex) for each device. All measurements were performed in triplicate, and the arithmetic mean of the three values was used. Using a digital caliper, measurements were recorded and entered into an Excel spreadsheet. Aftervisual verification with the K #10 file, the canals were instrumented with a #25.01 file tostandardize the apical region, and then instrumented with #25.02, #25.04, #25.06, #25.08, #25.10, and #25.12 files. After each instrumentation, electronic odontometry was checked with the #25.02 file. A measurement of 0.0 was adopted, with tolerance margins of ±0.5e ±1.0. Discrepancies between visual and electronic readings were statistically analyzed using ANOVA and Bonferroni tests, considered significant when P<0.05. Using the 0.0 mark and a measurement range of ±1.0, it was observed that the readings of the devices were similar in canals with different tapers (P>0.05), with a tendency toward underestimation. However, when the measurement range was narrowed to ±0.50, there was a significant statistical difference in the group that used Romiapex A-15 (P=0.0248),and when comparing the results of the two. Thus, it was concluded that the canal taper did not significantly influence the accuracy of the evaluated EALs, when the 0.0 referencepoint was used. Using a measurement range of ±0.5, the Romiapex A- 15 device exhibited greater accuracy, and finally, within the measurement range of ±1.0, both EALs showedexcellent precision.pt_BR
Appears in Collections:Mestrado Acadêmico em Ciências Odontológicas - Dissertações Defendidas

Files in This Item:
File Description SizeFormat 
FRANCISCO NATHIZAEL RIBEIRO GONÇALVES.pdf1.44 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.