Título : | Alternativa à Mesa de Tração Ortopédica: Um Protótipo Aplicável à Prática e ao Ensino Médico |
Autor : | LIMA, Diego Ariel de |
metadata.dc.contributor.advisor: | COELHO, Raquel Autran |
Fecha de publicación : | 2017 |
Citación : | LIMA, Diego Ariel de. Alternativa à Mesa de Tração Ortopédica: Um Protótipo Aplicável à Prática e ao Ensino Médico. 2017.Dissertação (Mestrado Profissional em Ensino em Saúde) - Centro Universitário Christus, Fortaleza, 2017. |
Resumen : | As mesas de tração ortopédicas são usadas como auxiliares em inúmeros procedimentos cirúrgicos, tais como a fixação de fraturas e artroscopia. Seu uso adequado auxilia na realização de cirurgias ortopédicas e no treinamento de residentes. O objetivo desse trabalho é apresentar um protótipo de um dispositivo externo de tração do membro inferior (portátil, de construção simples, que pode ser instalado em qualquer mesa cirúrgica radiotransparente) e comparar a qualidade de imagens radiográficas obtidas com o auxílio desse protótipo àquelas imagens obtidas com auxílio da mesa de tração convencional (MTC). Foi realizado um estudo transversal, observacional, onde 36 radiografias de membros inferiores, sendo 18 obtidas com a MTC e as demais com o protótipo, foram avaliadas por 9 médicos. Eles pontuaram cada imagem numa escala de 1 a 5, de acordo com a qualidade da imagem obtida. As respostas foram submetidas à análise estatística e consideradas significativas as comparações com valor de p < 0,05, com intervalo de confiança de 95%. Como resultado, não houve diferença estatisticamente significante entre os dois modelos. A concordância intra-observador foi de 76,13% para o protótipo e 82,69% para a MTC. A concordância inter-observador foi baixa nos dois modelos. Devido a seu peso e tamanho menores em relação à MTC e ao material utilizado na confecção da Mesa Protótipo (basicamente aço inoxidável tubular e plástico), o custo financeiro para a produção desta tornou-se bastante acessível. Assim, concluímos que a mesa protótipo é uma boa alternativa à mesa de tração ortopédica convencional. |
Descripción : | Orthopedic traction tables are used as auxiliaries in numerous surgical procedures, such as fracture fixation and arthroscopy. Its proper use assists in the performance of orthopedic surgeries and in the training of the residents. The objective of this work is to present a prototype of an external limb traction device (portable, simple construction that can be installed in any radiotransparent surgical table) and to compare the quality of radiographic images obtained with the aid of this prototype to those images obtained with the conventional drawbar. A cross-sectional and observational study was performed in which 36 x-rays of the lower limbs, 18 of which were obtained in the conventional traction table and the other in the prototype, were evaluated by nine physicians. They scored each image on a scale of 1 to 5, according to the quality of the image obtained. The answers were submitted to statistical analysis and the comparisons with a value of p <0.05 were considered significant, with a 95% confidence interval. As a result, there was no statistically significant difference between the two models. The intraobserver agreement was 76.13% for the prototype and 82.69% for the conventional one. The interobserver agreement was low in both models. Because of its smaller weight and size compared to the Conventional Table and the material used to make the Prototype Table (basically tubular and plastic stainless steel), the financial cost of producing the prototype has become quite affordable. Thus, we conclude that the prototype table is a good alternative to the conventional orthopedic tensile table. |
Palabras clave : | Mesa de tração Mesa de fratura Cirurgia ortopédica Protótipos ortopédicos Extremidade inferior |
URI : | https://repositorio.unichristus.edu.br/jspui/handle/123456789/690 |
Aparece en las colecciones: | Mestrado Profissional em Ensino em Saúde - Dissertações Defendidas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
DIEGO ARIEL DE LIMA.pdf | 15.08 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.